No counter-pressure or partial counter-pressure on a Meyer filler

Every counter-pressure fill starts with the bottle sealed against the valve and brought up to bowl pressure. If that does not happen, or only partly happens, the bottle fills too fast, foams and comes out low. These are the causes we check first.

No counter-pressure in the bottle

Likely causeWhat to do
Charging valve not opening: bent or binding outside valve lever or lever shaftLubricate the lever shaft and replace bent levers or shafts.
Mechanical latch set wrongSet the latch so the outside lever turns fully against its stop.
Blocked vent tubeClean the vent tube.
Bottle not sealing because the lift is sluggishCheck the lift air supply, lines and cylinders for leaks or blockage; clean and lubricate the cylinders.
Debris on the sealing rubberClean the sealing rubber.
Bottle not centered on the rubber: worn wear plates, grippers, infeed guide or star, or infeed star timingReplace worn parts and re-time the infeed star to the filler.
Broken snift valve springReplace the spring.

Partial counter-pressure

Likely causeWhat to do
Cut or damaged sealing rubberReplace the sealing rubber.
Leaking snift valveReplace the snift seat and check the spring.
Partly blocked vent tubeClean the vent tube.

Still stuck? Our technicians have spent more than 40 years on Meyer fillers and can usually find the cause faster on site. Call 843-851-3217 or ask about a machine audit.